Version

All versions

Explanation

The client is unable to establish a connection.

The following error message is output to $ALTIBASE_HOME/trc/altibase_boot.log.

ERR-7101d(errno=11) Protocol header error.(TCP 127.0.0.1:60264)
Protocol processing failed. Close connection...

Cause

The following error description can be viewed with the AltiErr utility: 

$ altierr 0x7101D
0x7101D ( 462877) cmERR_ABORT_PROTOCOL_HEADER_ERROR Protocol header error.(<0%s>)

# *Cause: Protocol header error

# *Action: Please send a bug report to the vendor.

This error message is written to altibase_boot.log when a client of a version incompatible with the server tried to establish a connection.

This error keeps a message history and does not adversely affect the Altibase server.

Action

If this error persists, find the client that is attempting to connect, then reinstall it with a version compatible with the server. 

Reference

If this error persists, find the client that is attempting to connect and reinstall it with a version compatible with the server. 

# How to check the server/client version

# Examples of server and client compatibility for different versions

 

Server Version

Client Version

Result

Remarks

Server Version > Client Version 
(5.3.3 or above)

6.3.1

5.3.3

Succeeds

Backward compatibility is supported for 5.3.3 or above.

Server Version > Client Version 
(5.3.1 or below) 

6.3.1

4.3.9

Fails

Backward compatibility is supported only if the version of both the server and client is 5.3.3 or above. 
Since the client version is older than 5.3.3, backward compatibility is not supported. For 4.3.9, connection succeeds only if the cm protocol versions are the same.

ServerVersion < Client Version 

6.1.1

6.3.1

Fails

If the version of the client is newer than the server, connection fails regardless of the Altibase version. 
The version of the client must be the same or older than the server.